Benefits of Wind Energy under the Consideration of External Cost

Avoided Emissions

In general, the benefits of wind energy are avoided emissions and avoided external costs as compared with conventional, mainly fossil-fuel based, electricity generation. Figure 4.1 (comparison of social costs of different electricity generation technologies) indicates that a kWh of wind energy (as for renewable energy in general) presents a negligible external cost in comparison with fossil-fuel based power systems. This fact illustrates the social and environmental advantages of wind energy and other renewables over conventional energy systems. Consequently, it is desirable to increase wind energy and other renewables in the electricity supply systems.

In recent years, the implementation of a variety of different renewable promotion instruments in Europe has resulted in significant amounts of renewable electricity generation, particularly wind generation. Without this, the corresponding amount of electricity generation would have been from conventional power plants. This means that renewable electricity generation has already displaced conventional electricity generation technologies and, subsequently, avoided significant amounts of emissions. Therefore, the external costs of total electricity generation have decreased as compared with the situation without any renewable electricity generation.

In the empirical analyses of avoided emissions and external costs in the EU27 Member States, Electricity Generation, Emissions and External Cost in the EU27 Countries in 2007, country-specific results are presented according to the quantity of external costs that have been already avoided due to wind generation in the different EU27 Member States. Moreover, in subsequent sections in Chapter 5, the avoided emissions and avoided external costs for different scenarios of wind deployment in the electricity systems of the EU27 Member States up to 2020 and 2030 are presented.

 

Externalities of Wind Energy

Although wind energy is a clean technology mainly due to the avoidance of air pollutant emissions, it is not totally free of impacts on the environment and human health. However, wind energy has very few environmental impacts in its operation. The most commonly discussed impacts on people are acoustic noise and visual intrusion, which some people find disturbing. Visual intrusion of the turbines along with ancillary systems in the landscape and noise are considered as amenity impacts of the technology. Other impacts deal with indirect pollution from the production of components and construction of the turbine, the collision of birds in flight with turbines and bird behavioural disturbance from blade avoidance, the impacts of wind turbine construction on terrestrial ecosystems, accidents affecting workers in manufacturing, construction and operation, and others. A comprehensive overview and discussion of these kinds of wind energy externalities is conducted in previous sections of this chapter.

Methodology for the Calculation of External Costs of Different Electricity Generation Technologies based on the EcoSense Model

The EcoSense Computer Model

To calculate the external costs of a given conventional power plant portfolio as well as the avoided external costs by wind energy, it is necessary to model the pathway of emissions from conventional power plants to the different receptors, such as humans, animals, plants, crops, materials etc., which may be located thousands of kilometres away. As air pollutants can damage a number of different receptors, the task of analysing the impacts of any given emission is fairly complex. To allow such complex analysis of external costs, a tool has been developed during the last 10 years in a major coordinated EU research effort, the EcoSense model. The basics of the model are explained below, as used in the calculations of the external costs of electricity generation in the EU27 Member States in Chapter 5.

EcoSense is a computer model for assessing environmental impacts and the resulting external costs of electricity generation systems. The model is based on the impact pathway approach of the ExternE project (see www.externe.info as well as

Pioneering Studies) and provides the relevant data and models required for an integrated impact assessment related to airborne pollutants (see also European Commission (1994).

 

EcoSense provides the wind-rose trajectory model for modelling the atmospheric dispersion of emissions, including the formation of secondary air pollutants. For any given point source of emissions (e.g. a coal fired power plant), the resulting changes in the concentration and deposition of primary and secondary pollutants can be estimated on a Europe-wide scale with the help of this model. Developed in the UK by the Harwell Laboratory, it covers a range of several thousand kilometres. The reference environment database, which is included in EcoSense, provides receptor-specific data as well as meteorological information based on the Eurogrid-co-ordinate system.

The impact pathway approach can be divided into four analytical steps (see e.g. Mora/ Hohmeyer (2005) in detail):

  • Calculation of emissions: The first step is to calculate emissions of CO2, SO2 and NOx per kWh from a specific power plant.
  • Dispersion modelling: Then air pollutant dispersion around the site of the specific plant is modelled. Based on meteorological data, changes in the concentration levels of the different pollutants can be calculated across Europe.
  • Impact analysis: Based on data for different receptors in the areas with significant concentration changes, the impacts of the additional emissions on these receptors can be calculated on the basis of so-called dose response functions. Important data on receptors included in the model database are, for example, population density and land use patterns.
  • Monetisation of costs: The last step is to monetise the impacts per kWh caused by the specific power plant. In this stage, the calculated physical damage to a receptor is valued on a monetary scale based on the best available approaches for each type of damage.

Input Data to the Model

Because the EcoSense model requires a specified site as a starting point for its pollutant dispersion modelling, one typical electricity generation site has been chosen for each country to assess the impacts and to calculate the costs caused by emissions from fossil-fuel fired power plants which may be replaced by wind energy. The coordinates at each site are chosen in order to locate the reference plants centrally in the electricity generating activities of each country. Thus, it is assumed that the chosen site represents approximately the average location of electricity generating activities of each country that has been chosen.

To control for effects caused by this assumption and to prevent extreme data results, a sensitivity analysis was carried out by shifting the geographical location of the plant. This analysis showed a relatively high sensitivity of external costs to the location of the electricity generation facilities. This is due to the very heterogeneous distribution of the different receptors in different parts of a country.

In order to run the model, the capacity of the conventional power plant, its full load hours of operation and the volume stream of exhaust gas per hour are required. The assumptions made for the calculations are shown in Table 4.1 for the different fossil-fuels of conventional electricity generation.

Fuel Type Capacity (MW) Full Load Hours per Year Volume Stream per Hour (m³)
Hard Coal 400 5000 1500000
Lignite 800 7000 3000000
Fuel Oil 200 2000 750000
Natural Gas
Derived Gas
200 2000 750000
Mixed Firing
Bot Specified
400 5000 1500000

Table 4.1 Assumed data for the calculation of the reference fossil-fuel based power plant technology

For each country, calculations have been performed for a representative conventional power plant location based on the specific national emission data for each fuel and each pollutant.

The evaluation in the EcoSense model includes damage from air pollutant emissions like SO2 and NOx (PM10 is negligible compared to SO2 and NOx) for the major receptors humans, crops and materials. For each of them, high, medium and low specific external costs are derived per country.

The costs of the anthropogenic greenhouse effect resulting from CO2 emissions are not modelled in the EcoSense model; they are based on estimates of Azar/Sterner (1996) and Watkiss et al (2005). Again, three different levels of specific external costs are implemented (high, medium, low) for the empirical calculation of CO2 related external costs in the different EU Member States.

Summing up: To calculate the external costs of conventional electricity generation technologies and, subsequently, the avoided external costs by the use of wind energy, the external costs resulting from air pollutants such as SO2 and NOx (calculated by EcoSense) have to be added to the external costs of the anthropogenic greenhouse effect resulting from CO2 emissions (not calculated by EcoSense).

Determination of Air Polluting Conventional Power Plants and Replaceable Segment of Conventional Electricity Generation by Wind Energy

This section identifies, as a first step, the different types of conventional power plants responsible for air pollutions (and, subsequently, for external costs caused by CO2, SO2 and NOx). Then a methodology is derived for the determination of the replaceable segment of conventional electricity generation technologies by wind energy. Finally, empirical data (annual generation, specific emissions) is presented for the portfolio of air polluting conventional power plants in several of the EU27 Member States.

Determination of Air Polluting Conventional Power Plants

In general, the load duration curve of different types of conventional power plants is split into three different segments: base load, intermediate load and peak load. Typical examples on conventional power plants operating in the different load duration segments are:

  • Base load: nuclear power plants, large run-of-river hydro power plants, lignite power plants, hard coal power plants;
  • Intermediate load: hard coal power plants, fuel oil fired power plants, combined cycle gas turbine plants;
  • Peak load: pumped-storage hydro power plants, open cycle gas turbine plants

With respect to above mentioned air polluting emissions (CO2, SO2 and NOx) several different kinds of fossil-fuel conventional power plants are candidates to be further investigated.

Replaceable Segment of Conventional Electricity Generation by Wind Energy

Due to its inherent variability, wind power can at present only replace specific segments of the load duration curve of conventional electricity generation. More precisely, wind energy can replace conventional power plants at the intermediate rather than base-load or peak-load segment.

Keeping this in mind, a reference system can be defined whereby wind energy can be expected to replace conventional power plants:

  • First, neither nuclear nor large hydro power plants are replaceable by wind energy, as both almost exclusively operate in the base load segment.
  • As pump hydro storage power plants are used to cover very short load peaks, they cannot be replaced by wind energy either, due to the latter's variable nature.
  • This leaves conventional electricity generation from the fossil-fuels: lignite, hard coal, fuel oil and gas.

However, this assumption can lead to an overestimation of the share of the replaced electricity generation by lignite, as this is predominantly used in the base load segment as well, and to an underestimation of substituted electricity from gas, which, due to the dynamic characteristics of gas fired power plants, lends itself perfectly to balance fluctuations in wind generation. As the current mode of operation of conventional power plants, the rules of their dispatch based on the so-called "merit order" and the dynamic behaviour of the different types of conventional power plants is well known, it can be safely assumed that a replacement of intermediate load by wind energy is the best description of the complexities of actual operation in the "real world".

For detailed empirical analyses, the contributions of the different fossil-fuel based power plant technologies to the intermediate load segment need to be specified. Due to the best statistics in this context available, data for the power plant in Germany are used as the basis for such analysis:

  • The load curves for one typical load day are derived for each relevant type of fuel and, furthermore, are taken as the basis for the calculation of shares of intermediate load.
  • In general, the highest load variations during one day are displayed by fuel oil and gas. Hard coal shows some variation, while electricity generation based on lignite is almost constant.

Although the characteristics of the load curves are based on the German electricity generation structure, conventional power plants have common fuel-specific technical and economic characteristics. Therefore, load curves are assumed to have similar day-to-day variations also in several other European countries. Based on these considerations, Table 4.2 sets out assumptions for the intermediate load shares, with the percentage figures being based on the total amount of electricity generated for each fuel.

Table 4.2 Share of Intermediate Load of different types of fossil-fuel power plant, source Auer

Fuel Type Share of Intermediate Load
Lignite 10 %
hard coal 30 %
mixed firing 50 %
fuel oil 100 %
natural/derives gas 100 %

The assumptions for intermediate load shares being replaceable by wind energy will remain the same for the years 2020 and 2030 for the fuel types lignite (10%), hard coal (30%), mixed firing (50%) and fuel oil (100%). For natural/derived gas the replaceable share will decrease from 100% (2007) to 92.5% (2020) and 85% (2030) in those EU Member States having no other flexible power plant technologies like pumped-hydro storage power plants. Due to significant shares of wind penetration in 2020 and 2030 a certain level of very flexible power plant types like combined-cycle gas turbines (CCGTs) is absolutely necessary to balance the electricity systems (see e.g. Auer et al (2007).

Fossil-fuel Based Electricity Generation and its Specific Emissions in the EU27 in 2007

In the following, the structure of total electricity generation (by fuel type) and, subsequently, the structure and fractions of fossil-fuel based electricity generation are presented on EU27 Member State's level in Figure 4.3 and 4.4 respectively. The empirical data is mainly derived from the Official 2006 Eurostat Statistics of the European Commission ("EU Energy in Figures - Pocket Book 2007/2008") and updated for the reference year 2007 with recent Platts European Power Plant Data Base 2008.

Figure 4.3. Total Electricity Generation (by Fuel Type) in the different EU27 Member States in 2007.

Figure 4.3. Total Electricity Generation (by Fuel Type) in the different EU27 Member States in 2007.

Figure 4.3 indicates that the absolute levels and shares of input fuels for electricity generation vary strongly between the different EU27 Member States. In particular, Figure 4.3 indicates those fossil-fuel based electricity generation technologies that may well be replaced by wind energy and/or other renewable energy sources in the future. As already mentioned above, neither base-load electricity generation technologies like nuclear and large hydro power nor peak-load technologies like pumped-storage hydro power plants are candidates to be replaced by wind energy. Also several other kinds of renewable electricity generation technologies are incorporated into the category of "others", since they are not of primary interest in further analyses when discussing fuel substitution by wind energy.

In Figure 4.4 exclusively several fossil-fuel based electricity generation technologies on EU27 Member State's level are presented in detail. The data presented here is the starting point for comprehensive in-depth analyses in subsequent sections.

Figure 4.4. Fossil-fuel Based Electricity Generation in the different EU27 Member States in 2007.

Figure 4.4. Fossil-fuel Based Electricity Generation in the different EU27 Member States in 2007.

Based on the portfolio of fossil-fuel based electricity generation in the different EU27 Member States in 2007 presented in Figure 4.4, the corresponding specific air pollutant emissions CO2, SO2, NOx and PM10 can be determined at a country level. The corresponding absolute air pollutant emissions of fossil-fuel based electricity generation are derived from a variety of different Member State's statistics as well as from official documents of the European Commission.

In this context it is important to note that the corresponding national studies and statistics take into account a variety of country-specific and technology-specific characteristics, e.g. the age-structure of the different power plants (and as a consequence also indirectly the primary fuel efficiency) in each of the EU27 Member States.

Figure 4.5 finally presents the results on the average specific CO2, SO2 and NOx emissions from fossil-fuel based electricity generation on Member State's level for the year 2007. In principle, the average specific emissions are less in the 'old' EU15 Member States (except Greece) than in the 'new' EU12 Member States. Bulgaria, Estonia, Greece, Romania and Slovenia are among the most air polluting countries within the EU27, at least in terms of CO2 emissions.

Figure 4.5. Specific Average Emissions (CO2, SO2, NOx) from Fossil-Fuel Based Electricity Generation in the different EU27 Member States in 2007.

Figure 4.5. Specific Average Emissions (CO2, SO2, NOx) from Fossil-Fuel Based Electricity Generation in the different EU27 Member States in 2007.

Figure 4.5 indicates that the difference in specific CO2 emissions from fossil-fuel generation is more than a factor of four between various EU27 Member States. This is related to differences in the fuel mix and because some Member States still have power plants with very low efficiencies. The distribution of SO2 emissions per kWh is also very different, as shown in Figure 4.5. This is related to the very heterogeneous sulphur content of fuel and the use of desulphurisation in only the most advanced Member States. Finally, NOx emissions differ between the countries according to the combustion process used, the combustion temperature, which is not optimal in all the Member States, and the scrubbing technologies employed.

The picture presented in Figure 4.5 will be further elaborated in subsequent sections when discussing the replaceable/avoidable as well as already avoided shares of fossil-fuel based electricity generation by wind energy (and other non-fossil-fuel based generation technologies) for the years 2007, 2020 and 2030.